The Elevator Earthquake Detector

○Accurate perception of the seismic information to avoid earthquake damage to the elevator ○Timely rescue of trapped person  ○Participate in the State administration of quality supervision the《2008QK21》subject research and participate in the National elevator shockproof standards drafting

Classification:

The Elevator Earthquake Detector

Product Consulting:

  • Product Details
    • Commodity name: The Elevator Earthquake Detector
    • Commodity ID: 02

    ○Accurate perception of the seismic information to avoid earthquake damage to the elevator ○Timely rescue of trapped person  ○Participate in the State administration of quality supervision the《2008QK21》subject research and participate in the National elevator shockproof standards drafting

    Product overview

    An elevator seismic monitor is a device used in conjunction with an elevator control system to enable an elevator to effectively enter controlled operation before or during an earthquake. Before the arrival of the earthquake, the elevator seismic monitor detects the seismic wave in advance, and outputs the alarm contact to control the elevator control system to make the elevator open the door at the near floor level, release the passengers in the elevator, save the life safety of the passengers, and ensure that the elevator equipment is not damaged. The system has the following advantages:

    (1) High-precision, low-noise seismic data acquisition;

    (2) Fast and accurate judgment of seismic events;

    (3) Two-stage trigger signal output. The instrument has three contact outputs, namely, the first alarm contact output, the second alarm contact output and the fault contact output, which are respectively connected to the elevator related system for the elevator system to operate and collect control signals.

     

    Technical parameters

     

    Product Model

    Technical parameters

    PQM3000 PQM3001
    Standby power supply None More than 8 hours
    Input voltage DC24V±10%  50Hz
    Output mode Three-way relay output
    Contact capacity 1.0A 30V DC,0.5A 125V AC
    frequency response 0.1Hz ~ 30Hz
    Level 1 alarm acceleration
    Threshold setting range
    0.2 m/s2 ~ 1 m/s2
    Secondary alarm acceleration
    Threshold setting range
    0.4 m/s2 ~ 3 m/s2
    Acquisition accuracy 0.01 m/s2
    Reset mode Automatic/Manual Reset
    Alarm record Article 100
    Power consumption of the whole machine < 5W
    Temperature -10 °c ~ 60 °c
    Relative humidity 93% without condensation
    Protection level IP65
    Dimensions 180mm × 155mm × 89mm

     

    Working principle

    The product collects the ground motion acceleration in the three directions of X/Y/Z when the earthquake occurs, and accurately detects the occurrence of the earthquake. When the P wave arrives, the acceleration sensor detects the vibration in the vertical direction in the early stage of the earthquake, I .e. outputs the corresponding electrical signal, which is sent to the microprocessor through the analog-to-digital converter for corresponding processing after filtering and amplification. When the S wave comes, the acceleration sensor detects the vibration in the horizontal direction, and outputs the corresponding electrical signal, which is sent to the microprocessor for corresponding processing through the analog-to-digital converter after filtering and amplification.

    The instrument has three relay output, respectively for the first alarm output, two alarm output and fault contact output, respectively, access to the elevator control operation system, for the elevator control system acquisition. The first-level alarm output is the output after the instrument detects the P-wave vibration or lower seismic motion acceleration in the early stage of the earthquake. It is a lower-level output and is used to judge that an earthquake may occur. After the first-level alarm relay operates, if the ground vibration signal of the second-level alarm is not reached within 10s, the product will automatically reset and the contact signal will disappear. The secondary alarm output corresponds to the output of higher ground motion acceleration and cannot be reset automatically. Professional elevator operators are required to check the elevator and perform manual reset after confirming that the elevator is free of any faults.

     

    System features

    ① Advanced Design

    • Take 3-axis acceleration sensor to accurately detect earthquake occurrence, P wave, S wave integration design;

    ② Simple installation and convenient debugging

    • Easy installation and maintenance, through the self-learning ability of the instrument, it can work normally without accurately determining the installation position;

    ③ Multi-level alarm

    • Multi-level classification alarm function to avoid false alarms;

    ④ Alarm value adjustment

    • By setting the software, the equipment alarm value can be adjusted on site;

    ⑤ Remote control and storage

    • Remote operation and function reset, alarm record storage function;

    ⑥ Self-inspection

    • Self-test function, automatic detection and calibration after the instrument itself fails, without human operation;

    ⑦ Output signal

    • Multiple sets of relay contact output signals to meet the different needs of elevator control;

    ⑧ Excellent workmanship

    • The shell is made of superior aluminum alloy material, beautiful appearance design, with a certain waterproof and dustproof function;

    Uninterruptible power supply

    • Effective power supply design, normally by the external DC24V power supply, in the case of external power supply automatically seamless to the battery power supply, to meet the special circumstances of the equipment normal alarm;

    Participate in the development of industry standards

    • Foreground Optoelectronics has actively participated in the development of industry standards for elevator earthquake alarms.

Product inquiry

Note: Please leave your E-mail and our professionals will contact you as soon as possible!

Cooperation cases

Shijingshan Military Sub-district of Beijing Municipality

Shijingshan Military Sub-district of Beijing Municipality

Hainan Building, Haikou City, Hainan Province

Hainan Building, Haikou City, Hainan Province

Radisson Hotel Tiandi Zhengzhou City, Henan Province

Radisson Hotel Tiandi Zhengzhou City, Henan Province

Zhengzhou Xinzheng International Airport

Zhengzhou Xinzheng International Airport